TrackSense Pro Basic Wireless Data Logger - Conductivity & Temperature Sensor

TrackSense Pro Basic Wireless Data Logger - Conductivity & Temperature Sensor

Ellab’s wireless TrackSense® Pro data loggers consist of high-end technology and resistant stainless steel that allows for immensely stable and accurate measurements within different thermal processes.

The combined conductivity & temperature sensor is sterilizable and has a conductivity range of 200 to 2000 µS/cm and a temperature range of 0 to +100 °C. Conductivity measurements apply to the control / monitoring of industrial processes and to validate the washing disinfection processes in hospitals governed by regulation EN ISO 15883:2009. The sensor can be used within the following industries:

  • Pharmaceutical Industry
  • Medical/Hospitals
  • Fermentation
  • Food and Beverage
  • Sugar Industry
  • Petro-Chemisty
  • Chemical Industry
  • Power Plants

All TrackSense® Pro data loggers can be configured with interchangeable sensors to measure temperature, pressure, relative humidity, CO2, and conductivity. The data loggers can easily be activated and read by the Multi reader station and can be combined with the Sky module for real time data via wireless communication.

 

Contact Sales
Technical Specifications

Sensor:

Interchangeable Combi Conductivity

Conductivity Range:

200 to 2000 μS/cm

Measuring Principle:

Electrical Conductivity

Sensor Element:

Conductivity / Pt1000 

Contact Material:

Peek (FDA compliant)

Dimensions L x D:

37 mm x 25 mm / 13 mm

Immersion Depth:

Minimum 25 mm

Conductivity Resolution:

0.1 μS/cm

Conductivity Accuracy:

± 1 μS/cm or ± 2.5 % of reading whichever is worse

IP Class:

IP67

Temperature Range:

0 °C to +100 °C*

Temperature Accuracy:

± 0.05 °C

Logger:

Pro Basic

Operating Temperature:

0 to +100 °C

House Material:

316 L Stainless Steel

Diameter:

25 mm

Length:

44 mm

Weight With Battery:

48 Grams

Memory Capacity:

60,000 Data Points

Minimum Sample Rate:

1 Second

Maximum Sample Rate:

24 Hours

Maximum Start Delay:

14 Days

Intrinsically Safe:

Ex II1GD Ex ia IIC T3 Ga, -30°C ≤ Tamb ≤ +105°C

Time Accuracy:

± 5 Seconds Per 24 Hours

Battery:

TSP Standard Battery

*The Conductivity sensor is not designed for steam sterilization, but can be autoclaved at +121 °C