jpgFeature/sdesk 696 implement raw brick http
TrackSense Pro Basic Wireless Data Logger - Vacuum & Temperature Sensor

TrackSense Pro Basic Wireless Data Logger - Vacuum & Temperature Sensor

The high quality wireless TrackSense® Pro data loggers consist of resistant stainless steel and offers high-end technology that allows for stable and highly accurate measurements within different thermal processes.

The Vacuum and Temperature Sensor has a pressure range of 0.0001 mBar to 1,000mBar and can document the temperature level at the SIP phase with its temperature range of -30 to +105°C. It can be used for various applications within the food and pharmaceutical industry and is especially ideal for low temperature applications such as lyophilization/Freeze drying.

All TrackSense® Pro data loggers can be configured with interchangeable sensors to measure temperature, pressure, relative humidity, CO2, and conductivity. The data loggers can easily be activated and read by the Multi reader station and can be combined with the Sky module for real time data via wireless communication.

 

Contact Sales
Technical Specifications

Sensor:

Interchangeable Vacuum

Pressure / Vacuum Measuring Range:

0.0001 mBar to 1,000 mBar (-30 to +80 °C)

Measuring Principle:

Pirani

Sensor Element:

Thermal Conductivity Vacuum Gauge / Pt1000 

Pressure / Vacuum Accuracy:

0.0005 mBar to 0.001 mBar:

20% of reading

0.001 mBar to 100 mBar:

15% of reading

100 mBar to 1,000 mBar

20% of reading

Pressure / Vacuum Sensor Response Time:

0.002 Sec.

Temperature Measuring Range:

-30 to +105 °C

Temperature Accuracy:

± 0.5 °C

Temperature Sensor Response Time:

<120 Seconds

Logger:

Pro Basic

Operating Temperature:

-30 to +105 °C

Operating Pressure*:

0.0001 mBar to 5 Bar

House Material:

316 L Stainless Steel

Diameter:

25 mm

Length:

44 mm

Weight With Battery:

48 Grams

Memory Capacity:

60,000 Data Points

Minimum Sample Rate:

1 Second

Maximum Sample Rate:

24 Hours

Maximum Start Delay:

14 Days

Intrinsically Safe:

Ex II1GD Ex ia IIC T3 Ga, -30°C ≤ Tamb ≤ +105°C

Time Accuracy:

± 5 Seconds Per 24 Hours

Battery:

TSP Standard Battery

If equipment is used in ATEX environment, special conditions for safe use stated in ATEX certificates section 17 must be considered.

Meer informatie
Newsletter Sign up

Deze website maakt gebruik van cookies om uw ervaring te verbeteren. Wij gaan er vanuit dat u hiermee akkoord gaat, maar mocht het gewenst zijn dan is dit uit te schakelen.

Lees meer
Sluiten