TrackSense Pro XL Wireless Data Logger - Single Flex High Temperature Sensor

TrackSense Pro XL Wireless Data Logger - Single Flex High Temperature Sensor

The high quality wireless TrackSense® Pro XL data loggers consist of resistant stainless steel and offers high-end technology that allows for stable and highly accurate measurements within different thermal processes. The XL logger is an enlarged logger with an extended battery capacity, which makes it exceptional for applications involving vast swings in temperature.

The Single Flex High Temperature Sensor has a temperature range of 0 to +400 °C with an accuracy of 0.5 °C (in range 0 to +400 °C). The sensor can be used for a wide range of applications and industries, but is ideal for high temperature applications, such as depyrogenation and ovens.

Ellab’s TrackSense® Pro data loggers can all be configured with interchangeable sensors to measure pressure, relative humidity, temperature, CO2, and conductivity. The data loggers are easily activated and read by the Multi reader station and when combined with the Sky module they provide real time date via wireless communication.

 

Contact Sales
Technical Specifications

Sensor:

Interchangeable Single Flex High Temperature

Temperature Measuring Range:

0 to +400 °C (>150 °C using Thermal Barrier)

Measuring Principle:

Electrical Resistance

Sensor Element:

Pt1000 

Diameter:

2 mm

Length:

150 - 1.000 mm

Position of Measuring Point from Round Tip:

3 mm

Accuracy:

0 to +400 °C:

± 0.5 °C

Sensor Response Time:

T-63%:

1.5 Second

T-90%:

2.9 Seconds

Logger:

Pro XL

Operating Temperature:

0 to +400 °C (>150 °C using Thermal Barrier)

Operating Pressure*:

0.001 mBar to 10 Bar ABS

House Material:

316 L Stainless Steel

Diameter:

25 mm

Length:

68.8 mm

Weight With Battery:

80 Grams

Memory Capacity:

60,000 Data Points

Minimum Sample Rate:

1 Second

Maximum Sample Rate:

24 Hours

Maximum Start Delay:

14 Days

Intrinsically Safe:

Ex II1GD Ex ia IIC T3 Ga,  -55°C ≤ Tamb ≤ +105°C

Time Accuracy:

± 5 Seconds Per 24 Hours

Battery:

TSP 150L Battery

If equipment is used in ATEX environment, special conditions for safe use stated in ATEX certificates section 17 must be considered.